Tillögur í öryggisátt Síða 9

Lög um RNSA, 35. gr.

Design of pulley fastener locking

Flug
Nr. máls: M-01913/AIG-14
Staða máls: Lokuð
06.08.2015

Tillaga í öryggisátt

The Icelandic Transportation Safety Board (ITSB) recommends to Technify Motors to reconsider the design of the crankshaft belt pulley fastener P/N 05-7223-K000501 in order to prevent loosening of the fastener.

Afgreiðsla

Technify Motors reconsidered the design of the crankshaft belt pulley fastener P/N 05- 7223-K000501 in order to prevent loosening of the fastener and provided a report to EASA. In the report different options of locking mechanism were considered. The preferred solution was to mark the bolt with torque seal and decided to implement it. This way, the security of the correct sit of the crankshaft main bolt could be checked during inspections, to see if it was loosening over time.

Design change to spoiler actuator

Flug
Nr. máls: M-00513/AIG-04
Staða máls: Lokuð
13.08.2015

Tillaga í öryggisátt

The Icelandic Transportation Safety Board (ITSB) recommends to Moog, in co-operation with the airplane’s manufacturer, set up a program to support fleet wide replacement of the blocking and thermal relief valve housing with the fatigue improved unit made from stainless steel.

Afgreiðsla

Moog has redesigned the Blocking and Thermal Relief Valve Housing with thicker material section and more radius in the area of the fracture surface. The redesigned Blocking and Thermal Relief Valve Housing is made from stainless steel instead of aluminum. This results in better fatigue performance of the Blocking and Thermal Relief Valve Housing. In addition the FAA has issued Safety Recommendation 15.115, a Boeing 757 airplane level safety issue, mandating evaluation of the spoiler actuator's blocking and thermal relief valve housing failure to determine appropriate corrective action.

Critical pulley fastener notification

Flug
Nr. máls: M-01913/AIG-14
Staða máls: Lokuð
06.08.2015

Tillaga í öryggisátt

The Icelandic Transportation Safety Board (ITSB) recommends to Technify Motors to issue a service letter to operators, advising of this incident and remind them never to loosen the belt pulley fastener in the crankshaft, due to its critical torque value.

Afgreiðsla

Technify Motors added several notes to repair procedures (RM-02-02) during which the mechanic might have the idea to demount the pulley and informed all registered users regarding the new versions.

Coupling the frequencies together to avoid multiple transmissions at the same time

Flug
Nr. máls: 20-085F016
Staða máls: Opin
27.12.2023

Tillaga í öryggisátt

In case a single ATCO monitoring multiple frequencies in the Keflavík Airport Tower, evaluate the feasibility of temporary coupling the frequencies together to avoid multiple transmissions at the same time.

Afgreiðsla

Conform to the required specifications and standards

Flug
Nr. máls: 19-082F020
Staða máls: Opin
15.10.2020

Tillaga í öryggisátt

Take the necessary quality assurance steps to ensure that connecting rod and the small end bushings conform to the required specifications and standards.

Afgreiðsla

Not actioned by Continental.

Change to emergency slide system

Flug
Nr. máls: M-01313/AIG-09
Staða máls: Lokuð
23.03.2016

Tillaga í öryggisátt

In conjunction with the manufacturer, ensure that necessary changes are made to the emergency escape slide design of RRJ-95B aircraft EASA certified under type certificate EASA.IM.A.176 to meet the maximum wind requirements of EASA CS-25.810(iv)

Afgreiðsla

EASA has contacted the manufacturer and the Interstate Aviation Committee-AR in order to review the compliance of the slides with the certification requirements.

Change the classification of the control zones

Flug
Nr. máls: 20-085F016
Staða máls: Opin
27.12.2023

Tillaga í öryggisátt

To change the classification of the control zones for Keflavik from class D airspace to class C airspace.

Afgreiðsla

Change of door design

Flug
Nr. máls: M-00511/AIG-05
Staða máls: Lokuð
10.04.2014

Tillaga í öryggisátt

The Icelandic Transportation Safety Board (ITSB) recommends to Precision Conversions that it reviews the structural design of the main cargo door with respect to the 45 knots maximum wind operation loading and make the necessary design changes in order to meet the requirements of FAA FAR and EASA CS, subchapters 25.301(a) and 25.303.

Afgreiðsla

Precision Conversions has modified the structural design of the main cargo door to support the intended 45 knots maximum wind operation limit in compliance with FAA FAR and EASA CS, subchapters 25.301(a) and 25.303.

Bætt utanumhald þjálfunar

Flug
Nr. máls: M-02012/AIG-16
Staða máls: Lokuð
17.09.2014

Tillaga í öryggisátt

RNSA beinir því til fisfélagsins Sléttunnar að utanumhald um framgang þjálfunar flugnema verði bætt.

Afgreiðsla

Fisfélagið Sléttan í samvinnu við fisfélag Reykjavíkur og Samgöngustofu hefur hafið vinnu við endurskoðun verklagshandbóka fisfélaga. Vonast er til að þetta klárist vorið 2016.

Bætt eftirfylgni vegna símhringinga í 112

Flug
Nr. máls: 22-010F002
Staða máls: Opin
02.05.2024

Tillaga í öryggisátt

RNSA beinir því til Neyðarlínunnar að bæta eftirfylgni vegna símhringinga án skýrrar tjáningar þess sem hringir.

Afgreiðsla